ハードドライブに不良ブロックが8つあります。

ハードドライブに不良ブロックが8つあります。

潜在的に破損したハードドライブのSMARTメッセージは次のとおりです。

smartctl 6.6 2016-05-31 r4324 [x86_64-linux-4.18.0-15-generic] (local build)
Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Model Family:     Toshiba 2.5" HDD MK..76GSX
Device Model:     TOSHIBA MK3276GSX
Serial Number:    9296Y9FOF
LU WWN Device Id: 5 000039 44d00306b
Firmware Version: GS001C
User Capacity:    320,072,933,376 bytes [320 GB]
Sector Size:      512 bytes logical/physical
Rotation Rate:    5400 rpm
Form Factor:      2.5 inches
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   ATA8-ACS (minor revision not indicated)
SATA Version is:  SATA 2.6, 3.0 Gb/s (current: 3.0 Gb/s)
Local Time is:    Fri May 17 11:29:47 2019 UTC
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x82) Offline data collection activity
                    was completed without error.
                    Auto Offline Data Collection: Enabled.
Self-test execution status:      ( 121) The previous self-test completed having
                    the read element of the test failed.
Total time to complete Offline 
data collection:        (  120) seconds.
Offline data collection
capabilities:            (0x51) SMART execute Offline immediate.
                    No Auto Offline data collection support.
                    Suspend Offline collection upon new
                    command.
                    No Offline surface scan supported.
                    Self-test supported.
                    No Conveyance Self-test supported.
                    Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                    power-saving mode.
                    Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                    General Purpose Logging supported.
Short self-test routine 
recommended polling time:    (   2) minutes.
Extended self-test routine
recommended polling time:    (  81) minutes.
SCT capabilities:          (0x003f) SCT Status supported.
                    SCT Error Recovery Control supported.
                    SCT Feature Control supported.
                    SCT Data Table supported.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x002f   100   100   050    Pre-fail  Always       -       0
  2 Throughput_Performance  0x0027   100   100   050    Pre-fail  Always       -       0
  3 Spin_Up_Time            0x0023   100   100   002    Pre-fail  Always       -       1223
  4 Start_Stop_Count        0x0032   100   100   000    Old_age   Always       -       5405
  5 Reallocated_Sector_Ct   0x0033   100   100   010    Pre-fail  Always       -       0
  7 Seek_Error_Rate         0x002f   100   100   050    Pre-fail  Always       -       0
  8 Seek_Time_Performance   0x0025   100   100   050    Pre-fail  Offline      -       0
  9 Power_On_Minutes        0x0032   089   089   000    Old_age   Always       -       75h+35m
 10 Spin_Retry_Count        0x0033   208   100   030    Pre-fail  Always       -       0
 12 Power_Cycle_Count       0x0032   100   100   000    Old_age   Always       -       5380
183 Runtime_Bad_Block       0x0032   100   100   001    Old_age   Always       -       0
184 End-to-End_Error        0x0033   100   100   097    Pre-fail  Always       -       0
185 Unknown_Attribute       0x0032   100   100   001    Old_age   Always       -       65535
187 Reported_Uncorrect      0x0032   001   001   000    Old_age   Always       -       599
188 Command_Timeout         0x0032   100   099   000    Old_age   Always       -       8
189 High_Fly_Writes         0x003a   100   100   001    Old_age   Always       -       0
190 Airflow_Temperature_Cel 0x0022   070   047   040    Old_age   Always       -       30 (Min/Max 29/30)
191 G-Sense_Error_Rate      0x0032   100   100   000    Old_age   Always       -       557
192 Power-Off_Retract_Count 0x0022   100   100   000    Old_age   Always       -       10092698
193 Load_Cycle_Count        0x0032   088   088   000    Old_age   Always       -       127749
196 Reallocated_Event_Count 0x0032   100   100   000    Old_age   Always       -       0
197 Current_Pending_Sector  0x0032   100   100   000    Old_age   Always       -       1
199 UDMA_CRC_Error_Count    0x0032   200   200   000    Old_age   Always       -       0

SMART Error Log Version: 1
ATA Error Count: 1515 (device log contains only the most recent five errors)
    CR = Command Register [HEX]
    FR = Features Register [HEX]
    SC = Sector Count Register [HEX]
    SN = Sector Number Register [HEX]
    CL = Cylinder Low Register [HEX]
    CH = Cylinder High Register [HEX]
    DH = Device/Head Register [HEX]
    DC = Device Command Register [HEX]
    ER = Error register [HEX]
    ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.

Error 1515 occurred at disk power-on lifetime: 4512 hours (188 days + 0 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 41 3a ed c8 de 6b  Error: UNC at LBA = 0x0bdec8ed = 199149805

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  60 08 38 e8 c8 de 40 08      03:59:07.091  READ FPDMA QUEUED
  ef 10 02 00 00 00 a0 00      03:59:07.090  SET FEATURES [Enable SATA feature]
  ec 00 00 00 00 00 a0 00      03:59:07.090  IDENTIFY DEVICE
  ef 03 45 00 00 00 a0 00      03:59:07.090  SET FEATURES [Set transfer mode]
  ef 10 02 00 00 00 a0 00      03:59:07.090  SET FEATURES [Enable SATA feature]

Error 1514 occurred at disk power-on lifetime: 4512 hours (188 days + 0 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 41 c2 ed c8 de 6b  Error: UNC at LBA = 0x0bdec8ed = 199149805

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  60 08 c0 e8 c8 de 40 08      03:59:03.044  READ FPDMA QUEUED
  61 28 b8 c0 c8 de 40 08      03:59:03.044  WRITE FPDMA QUEUED
  ef 10 02 00 00 00 a0 00      03:59:03.043  SET FEATURES [Enable SATA feature]
  ec 00 00 00 00 00 a0 00      03:59:03.043  IDENTIFY DEVICE
  ef 03 45 00 00 00 a0 00      03:59:03.043  SET FEATURES [Set transfer mode]

Error 1513 occurred at disk power-on lifetime: 4512 hours (188 days + 0 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 41 4a ed c8 de 6b  Error: UNC at LBA = 0x0bdec8ed = 199149805

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  60 08 48 e8 c8 de 40 08      03:58:59.012  READ FPDMA QUEUED
  ef 10 02 00 00 00 a0 00      03:58:59.012  SET FEATURES [Enable SATA feature]
  ec 00 00 00 00 00 a0 00      03:58:59.011  IDENTIFY DEVICE
  ef 03 45 00 00 00 a0 00      03:58:59.011  SET FEATURES [Set transfer mode]
  ef 10 02 00 00 00 a0 00      03:58:59.010  SET FEATURES [Enable SATA feature]

Error 1512 occurred at disk power-on lifetime: 4512 hours (188 days + 0 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 41 ba ed c8 de 6b  Error: UNC at LBA = 0x0bdec8ed = 199149805

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  60 08 b8 e8 c8 de 40 08      03:58:54.985  READ FPDMA QUEUED
  ef 10 02 00 00 00 a0 00      03:58:54.984  SET FEATURES [Enable SATA feature]
  ec 00 00 00 00 00 a0 00      03:58:54.983  IDENTIFY DEVICE
  ef 03 45 00 00 00 a0 00      03:58:54.983  SET FEATURES [Set transfer mode]
  ef 10 02 00 00 00 a0 00      03:58:54.983  SET FEATURES [Enable SATA feature]

Error 1511 occurred at disk power-on lifetime: 4512 hours (188 days + 0 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 41 0a ed c8 de 6b  Error: UNC at LBA = 0x0bdec8ed = 199149805

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  60 08 08 e8 c8 de 40 08      03:58:50.953  READ FPDMA QUEUED
  60 80 f8 28 c9 de 40 08      03:58:50.953  READ FPDMA QUEUED
  ef 10 02 00 00 00 a0 00      03:58:50.952  SET FEATURES [Enable SATA feature]
  ec 00 00 00 00 00 a0 00      03:58:50.952  IDENTIFY DEVICE
  ef 03 45 00 00 00 a0 00      03:58:50.951  SET FEATURES [Set transfer mode]

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
# 1  Extended offline    Completed: read failure       90%      4508         199149805
# 2  Short offline       Completed: read failure       90%      4508         199149805
# 3  Short offline       Completed: read failure       90%      4507         199149805
# 4  Extended offline    Completed: read failure       90%      4507         199149805
# 5  Short offline       Completed: read failure       90%      4507         199149805
# 6  Extended offline    Completed: read failure       90%      4507         199149805
# 7  Short offline       Completed without error       00%         2         -

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

Current_Pending_Sector値は8回信号を1受信しましたError: UNC at LBA = 0x0bdec8ed = 199149805。 Ubuntu 18.04もbadblocks実行中ですが、エラーが発生します8/0/0。から199149800までのセクタ199149807は破損していると見なされます。

私はこれらのパラメータについて議論の余地があるいくつかの見解を読んだ。存在するこの回答たとえば、Current_Pending_Sector健康なディスクはそうではありません。増加する。他の人は、ゼロ以外のすべての値がディスクの交換を強くお勧めします。

  • このドライブの状態はどれほど深刻ですか?
  • 実行できる他の明示的なテストがありますか?

答え1

ハードドライブに不良セクタ(*)が8つあることは問題になりません。
不良セクタの数は時間の経過とともに増加すると予想されます。ゆっくり
ディスクに書き込むと、コントローラは書き込みエラーを検出し、ディスク上の他のセクタにデータを書き込みます。ディスクチェッカーはまだ不良ブロックとしてマークされますが、そこには何も記録されません。だからあなたは本当に気にしません。

(*) 問題が発生する場所は、ブロックが失敗した場合です。後ろにが書かれています。これはアプリケーションで読み取りエラーとして表示されます。それから楽しみが始まります。バックアップから検索または再作成できますか?その場合、他のブロックに書き込まれます。それ以外の

場合は、ドライブにパフォーマンスの問題(読み取り/書き込みエラーなど)がない場合でも心配しないでください。年に数回不良セクタの数を確認してください。
読み取り/書き込みエラーによるパフォーマンス上の問題がある場合(注:これはシステムの速度がどれほど遅いかについての開発者/ユーザーの苦情ではありません)。不良ブロック数が大幅に増加したことを確認できます。これはディスクエラーを示します。

昔は許容できるほど悪い数値(総ブロックの割合)がありました(おそらく5%?)。その数が増加し始めた場合(最大8%?)、お金があり、ダウンタイムがある場合は、ドライブの交換を検討できます。
今日のドライブの信頼性が向上しました。一部のハードウェアメーカーは、ドライブに不良セクタがないと主張することもあります。 (ROTFL).
おそらく他の人が心配する不良セクタの数について良い数を持っているかもしれません。

IMHOディスクにエラーが発生しませんでした。まったく心配する必要はありません。
$0.02

答え2

最初にすることは、バックアップ、バックアップ、バックアップです!いずれにせよ、重要なデータは、同じディスクにパーティションを分割するのではなく、別のディスクに計画されたバックアップシステムを置く必要があります。

デフォルトに戻って、まずシステム電源が100%安定しており、電源を変更せずにハードドライブが常にオンになっていて、温度/空気/湿度条件が最適であれば、ディスク障害の99%を回避できます。実際、これらの条件は次のとおりです。頻繁に満たされません(これらの条件を最適化できるようにするためのものです)。

メカニカルディスクを使用する場合、予想寿命はディスクのデータ断片化状態とディスク使用頻度によって大きく異なります。これは、2つの事実がディスクヘッドが大量に移動したり大量に移動したりせず、ディスクスペースを消費するためです。ディスクの寿命を考慮してデータの断片化を確認し、必要に応じて最終的に計画どおりに修正することをお勧めします。

ほとんどの場合、メカニカルディスクは故障の直前から奇妙な騒音を出し始めます。

停電はメカニカルディスクに非常に有害なので、できるだけ避けてください。

あなたの質問に戻って、不良セクタが懸念の原因ですか?私の回復経験によると、各ディスクモデルによって異なりますが、一部は1000個の不良セクタの後でも堅牢な状態を維持しますが、他の一部は不良セクタが発生した後すぐに死にます。技術は同じで、メーカーごとにそれを適用し、さらに1つのモデルも異なります。他の人から。すべてのディスクと同様に、1つの明確なことは、この値が増加する傾向があるため、注意深く観察する必要があることです。

ほとんどの最新のシステムファイルNTFS / EXT4およびディスクファームウェアには、優れた不良セクタ管理システムがあります。ディスクに不良セクタがほとんどない場合は、心配する必要はありません。データの損失と破損が発生する可能性があります。

一部の製造元には、自分の状況について私が見つけたディスクをより深く調査するための独自のツールがありますが、ToshibaStorageDiagnosticToolこれはあなたがすでに持っているものよりも多くの情報を提供しないようです。これらのツールは警告についてのみ通知できます。特定の状況では、ダウンするまで警告を表示しないディスクが多いため、常に警告モード(バックアップなど)を維持することをお勧めします。

最後に、不良セクタを修復する技術があります。これは、不良セクタにもかかわらずディスクが安定している種類の場合に便利です。 ハードドライブプレーヤーとても良いです。 (私は彼らがこの技術の発明者だと思います)

結論として:SSDまたはHDDに不良セクタがあるかどうかにかかわらず、ディスクを観察し、他のデバイスから定期的にバックアップしてください。

関連情報