私はgsmartcontrol
「エラー」タブを使用していますが、次のように言います。
Complete error log:
SMART Error Log Version: 1
ATA Error Count: 398 (device log contains only the most recent five errors)
CR = Command Register [HEX]
FR = Features Register [HEX]
SC = Sector Count Register [HEX]
SN = Sector Number Register [HEX]
CL = Cylinder Low Register [HEX]
CH = Cylinder High Register [HEX]
DH = Device/Head Register [HEX]
DC = Device Command Register [HEX]
ER = Error register [HEX]
ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 398 occurred at disk power-on lifetime: 125 hours (5 days + 5 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
84 51 01 0f 08 00 00 Error: ICRC, ABRT at LBA = 0x0000080f = 2063
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
60 10 00 00 08 00 40 00 00:09:15.084 READ FPDMA QUEUED
ec 00 00 00 00 00 00 00 00:09:15.006 IDENTIFY DEVICE
ef 10 03 00 00 00 00 00 00:09:14.990 SET FEATURES [Enable SATA feature]
ef 10 02 00 00 00 00 00 00:09:14.974 SET FEATURES [Enable SATA feature]
b1 c1 00 00 00 00 00 00 00:09:14.959 DEVICE CONFIGURATION FREEZE LOCK [OBS-ACS-3]
Error 397 occurred at disk power-on lifetime: 125 hours (5 days + 5 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
84 51 01 0f 08 00 00 Error: ICRC, ABRT at LBA = 0x0000080f = 2063
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
60 10 00 00 08 00 40 00 00:09:14.756 READ FPDMA QUEUED
ec 00 00 00 00 00 00 00 00:09:14.678 IDENTIFY DEVICE
ef 10 03 00 00 00 00 00 00:09:14.662 SET FEATURES [Enable SATA feature]
ef 10 02 00 00 00 00 00 00:09:14.646 SET FEATURES [Enable SATA feature]
b1 c1 00 00 00 00 00 00 00:09:14.631 DEVICE CONFIGURATION FREEZE LOCK [OBS-ACS-3]
Error 396 occurred at disk power-on lifetime: 125 hours (5 days + 5 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
84 51 01 0f 08 00 00 Error: ICRC, ABRT at LBA = 0x0000080f = 2063
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
60 10 00 00 08 00 40 00 00:09:14.508 READ FPDMA QUEUED
60 01 00 02 00 00 40 00 00:09:14.506 READ FPDMA QUEUED
60 04 00 07 00 00 40 00 00:09:14.506 READ FPDMA QUEUED
60 01 00 00 00 00 40 00 00:09:14.506 READ FPDMA QUEUED
60 01 00 00 00 00 40 00 00:09:14.506 READ FPDMA QUEUED
Error 395 occurred at disk power-on lifetime: 125 hours (5 days + 5 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
84 51 01 0f 88 b9 0a Error: ICRC, ABRT at LBA = 0x0ab9880f = 179931151
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
60 10 00 00 88 b9 40 00 00:00:15.234 READ FPDMA QUEUED
ec 00 00 00 00 00 00 00 00:00:15.156 IDENTIFY DEVICE
ef 10 03 00 00 00 00 00 00:00:15.141 SET FEATURES [Enable SATA feature]
ef 10 02 00 00 00 00 00 00:00:15.125 SET FEATURES [Enable SATA feature]
b1 c1 00 00 00 00 00 00 00:00:15.109 DEVICE CONFIGURATION FREEZE LOCK [OBS-ACS-3]
Error 394 occurred at disk power-on lifetime: 125 hours (5 days + 5 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
84 51 01 57 d1 54 08 Error: ICRC, ABRT at LBA = 0x0854d157 = 139776343
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
60 08 00 50 d1 54 40 00 00:00:14.984 READ FPDMA QUEUED
ec 00 00 00 00 00 00 00 00:00:14.922 IDENTIFY DEVICE
ef 10 03 00 00 00 00 00 00:00:14.906 SET FEATURES [Enable SATA feature]
ef 10 02 00 00 00 00 00 00:00:14.891 SET FEATURES [Enable SATA feature]
b1 c1 00 00 00 00 00 00 00:00:14.875 DEVICE CONFIGURATION FREEZE LOCK [OBS-ACS-3]
どういう意味ですか?このエラーを防ぐ方法は?
答え1
「ICRCの間違い」とは、次のことを意味します。転送中にデータが破損しています。;ドライブの寿命を考慮すると、最も可能性の高い原因は損傷したケーブルです。全体的に考えられる原因は次のとおりです。
- ケーブルが破損しています。問題が解決しない場合は、ケーブルを再取り付けして交換してみてください。
- 不良チップセット(マザーボードが非常に古くない場合の可能性は低い)
- 運転がうまくいかない。
最後のステップに達したら、別のシステムでドライブを試してみてください。